Mouse Anti-Respiratory Syncytial Virus (RSV) Antibody IgG Titer Serologic Assay Kit (Trimeric Prefusion Glycoprotein)
Catalog Number:
Q72Y17
Background:
Respiratory syncytial virus (RSV) annually causes approximately 3 million acute lower respiratory infections in children and is typified by recurrent infections in infants. Two major RSV subtypes, A and B, circulate with 1-2 epidemic periods per year. The RSV fusion (F) protein is a dominant antigen and a prominent vaccine target. A rapid and effective assay kit detecting the levels of anti-RSV F from both subtypes A and B in mouse serum can facilitate research on antibodies produced in response to RSV vaccine candidates.
Applications:
This kit is developed for serologic test for mouse IgG titer of Anti-RSV F antibody in serum/plasma or purified mouse antibody (monoclonal & polyclonal) in vitro. It is for research use only.
Ordering:
Q72Y17-A for plate pre-coated with prefusion-stabilized trimeric fusion (F) protein of RSV subtype A strain A2.
Q72Y17-B for plate pre-coated with prefusion-stabilized trimeric fusion (F) protein of RSV subtype B strain 18537.
Biosafety Level:
BSL-1
Organism:
Respiratory syncytial virus (RSV)
Assay Principles:
This kit is developed for a standard indirect-ELISA format, providing a rapid detection of anti-RSV fusion (F) protein mouse IgG in serum. The kit consists of high-bind detachable 96-well plate pre-coated with trimeric F protein, Positive control, Negative Control, an HRP-Anti-Mouse IgG secondary antibody, TMB and dilution/wash/stop buffer.
Use protocol (4 simple steps):
- Detach wells from plate based on your samples and keep at room temperature. Dilute your samples, positive and negative controls in sample dilution buffer and add them to wells (0.1 ml/well). Incubate at 37°C for 1 hour or room temperature for 1.5 hour. Wash wells 4 times by wash solution (0.3 ml/well)
- Dilute the Secondary antibody HRP-Anti-Mouse IgG by wash solution and add to each well (0.1 ml/well). Incubate at room temperature for 0.5-1 hour. Avoid light by foil. Wash wells as mentioned.
- Add TMB to each well (0.1 ml/well) and incubate at room temperature for 10-30 minutes.
- Stop the substrate reaction by adding stop solution (0.1 ml/well). Absorbance (OD) is calculated as the absorbance at 450 nm. The OD Value reflects the amount of antibody bound.
Storage and shipping condition:
Shipment with room temperature. The unopened kit is stable for 6 months from the date of manufacture when stored at 2°C to 8°C. Avoid light. The shelf life is 60 days from the date of opening.